Warp Gasification
team@univastum.com
Knowledge Base
Chief Technology Officer
Peter Kalenuk
Industrial Waste-to-Steam
Integrated Waste-to-Steam facility for industrial client
Spain
Municipal Waste-to-Electricity
Modular Waste-to-Energy facility for municipal solid waste
Romania
investors@univastum.com
Chief Investment Officer
Eben Klynsmith
Our Approach
Work With Us
Insights & News
Press Kit
mt@univastum.com
Chief Marketing & Communications Officer
Matthew Tucker

Waste-to-Steam for Industrial Processes

Modular Industrial Steam Generation from Waste Based on WARP Gasification Technology
The modular Waste-to-Steam system converts qualified waste-derived and biomass feedstocks into conditioned syngas, which is used to generate industrial process steam.

A standard project configuration combines fuel preparation, one or more WARP gasification modules and a dedicated syngas-fired steam-generation system.
Waste preparation → WARP gasification → Conditioned syngas → Steam boiler → Industrial steam

One standard WARP module provides the following indicative operating figures:

How Waste-to-Steam Works

The Waste-to-Steam process comprises three main stages.

  1. Waste Preparation

The preparation system is configured according to the type and characteristics of the incoming feedstock.
For unsorted MSW, the system includes sorting, removal of inert materials, shredding, drying and homogenisation to produce fuel meeting WARP specifications. Prepared RDF, SRF, biomass and other qualified fuels may require only project-specific conditioning.

2. Waste Gasification

Prepared feedstock is converted into syngas using WARP gasification technology. The syngas is cooled and prepared within the WARP process before being supplied to the steam-generation system.
The conditioned syngas serves as the primary fuel for industrial steam production.

3. Steam Generation

Conditioned syngas is used in a dedicated boiler to generate industrial process steam. The steam-generation system is configured according to the required steam pressure, temperature, flow rate and operating conditions.
Two indicative dry saturated-steam conditions are considered:
  • 10 bar(g) — approximately 184°C
  • 12 bar(g) — approximately 192°C
Other steam conditions can be engineered according to meet the requirements of the receiving industrial process.

Standard Waste-to-Steam Configuration

The following parameters describe a representative Waste-to-Steam configuration based on one standard WARP module.

Indicative Parameters per Module

* For MSW projects, approximately 40,000 tonnes per year of prepared feedstock may require up to 80,000 tonnes per year of incoming MSW, depending on waste composition, moisture content and preparation requirements.
Steam-production figures represent preliminary boiler-generation estimates rather than guaranteed steam delivery at the customer battery limit. Actual performance depends on prepared-fuel characteristics, steam conditions, boiler efficiency and the project-specific mass and energy balance.

Modular Scaling

Waste-to-Steam capacity can be scaled by combining multiple standard WARP modules.

For preliminary screening, the following prepared-fuel characteristics are considered:
  • Prepared MSW-derived fuel: approximately 12–18 MJ/kg LHV
  • RDF/SRF: approximately 14–22 MJ/kg LHV
The steam-output calculations are based on approximately 5 t/h of prepared fuel per module, dry saturated steam at 10–12 bar(g) and feedwater at approximately 90°C.

Indicative Parameters per Module

* Incoming MSW and prepared feedstock represent the same waste stream before and after preparation and should not be added together.
The steam-production values are indicative estimates for preliminary project screening. Final boiler performance and steam delivery are determined through the project-specific mass and energy balance.

Steam System Configuration

Multiple WARP modules can supply a common steam-generation system or operate with separate boiler systems.

The configuration is selected according to continuous steam demand, prepared-fuel availability, steam conditions, maintenance requirements and planned project development phases.

For example, an industrial site requiring approximately 40 t/h of continuous saturated steam may be served by a two-module WARP configuration, depending on fuel characteristics and the required steam conditions.

Peak demand, backup capacity, redundancy and condensate return are addressed during project-specific steam-system design.

Industrial Steam Applications

Waste-to-Steam is intended primarily for industrial facilities with stable and predictable steam demand.

Typical applications include:

  • Food and beverage processing
  • Textile manufacturing
  • Pulp and paper production
  • Chemical manufacturing
  • Industrial drying and evaporation
  • Washing, cleaning and sterilisation
  • General industrial process heating and plant utilities
Steam pressure, temperature, quality and delivery conditions are defined according to the requirements of the receiving industrial process. The final steam delivery point is established at the customer battery limit.

Heat Integration

Thermal energy recovered during syngas cooling can be integrated into the overall plant energy system. Depending on the project configuration, recovered heat may be used for fuel drying, boiler feedwater heating and other suitable industrial heating requirements.

Heat recovery is incorporated into the overall project energy balance to avoid double-counting energy outputs.

Project Delivery Models

Univastum Waste-to-Steam projects can be delivered through equipment supply, integrated turnkey solutions or long-term Energy-as-a-Service arrangements.

For suitable larger projects, Build–Own–Operate (BOO) and Build–Own–Operate–Transfer (BOOT) structures may also be considered.

A preliminary project assessment can begin with the available waste or prepared-fuel volume, required steam capacity, steam delivery conditions and basic site requirements.